Leave Your Message

ZYD two-stage high-efficiency vacuum oil filter

Filtration Unit

ZYD two-stage high-efficiency vacuum oil filter

 

 

  • Product name ZYD two-stage high-efficiency vacuum oil filter
  • Working vacuum degree(MPa) -0.08—-0.0999
  • Constant temperature control range(℃) 20~80
  • Nominal pressure(MPa) ≤0.5
  • Power Supply(V) 380V/50Hz(Or according to user needs)
  • Work noise(dB(A)) ≤78
  • Application industry Metallurgy, petrochemicals, textiles, mechanical processing, mining,engineering machinery, etc Filter media:Hydraulic oil, lubricating oil, engine oil etc

ZYD dual stage high-efficiency vacuum oil filter is a widely used equipment in industries such as machinery, transportation, and railways, especially in the field of electricity (such as power plants, power stations, power companies, substations, etc.), which has significant advantages. This equipment is particularly suitable for large-scale transmission and transformation voltage equipment above 110KV and national main transformer power grids, and is also suitable for use in areas with an altitude of over 500 meters. The following is a detailed introduction to the ZYD two-stage high-efficiency vacuum oil filter:

ZYD two-stage high-efficiency vacuum oil filter (1)92iZYD two-stage high-efficiency vacuum oil filter (2)ax6ZYD two-stage high-efficiency vacuum oil filter (3)n2d

Product features of ZYD two-stage high-efficiency vacuum oil filter

High vacuum and high pumping speed: This equipment has extremely high vacuum degree and high pumping speed capability, which can meet the needs of transformer body vacuum pumping and vacuum oil injection on installation or maintenance sites, and simultaneously complete deep purification treatment of transformer oil.

Efficient removal: Using nano molecular material filtration and complex three-dimensional flash evaporation technology, the water, gas, and impurities in transformer oil are efficiently removed, significantly improving the pressure resistance strength and oil quality of the oil.

Intelligent Control: Optional PLC intelligent control, touch screen operation, and dynamic display, making operation more convenient and intelligent.

Humanized design: The equipment features low noise, simple operation, long maintenance intervals, and low energy consumption, reducing operating costs.

Safety protection: The entire machine is equipped with interlocking safety protection, including interlocking protection for the oil discharge system, vacuum system, and heating system, as well as leakage and overload shutdown devices, to ensure the safe operation of the equipment.

Parameter Name

Unit

ZYD-30

ZYD-50

ZYD-100

ZYD-150

ZYD-200

ZYD-300

ZYD-500

Flow rate

L/H

1800

3000

6000

9000

12000

15000

30000

Working vacuum
degree

MPa

-0.08—-0.0999

Working
pressure

MPa

≤0.5

Constant
temperature
control range

20—80

Power Supply

V

380V/50Hz(Or according to user needs)

Work noise

dB(A)

 dB(A) ≤78

Total power
(optional)

KW

30+5

30+5

60+7

3*30+10

4*30+12

6*30+16

8*30+35

Import and export
pipe diameter

mm

25

32

40

50

50

65

80

Weight

Kg

600

800

1000

1300

1800

2100

3500

External
dimensions

L

cm

120

125

157

175

175

180

200

W

cm

120

125

140

160

160

170

180

H

cm

160

175

200

215

215

225

230

The use of ZYD two-stage high-efficiency vacuum oil filter

ZYD dual stage high-efficiency vacuum oil filter is widely used in power plants, power stations, power companies, metallurgy, petrochemicals, machinery, transportation, railways and other industries, especially for on-site maintenance of transformers in large substations above 110KV, as well as deep purification treatment of high-grade new oil, imported oil, transformer oil, ultra-high pressure transformer oil and other oil products. In addition, the device can also be used for vacuum oil injection and drying of transformers, and can achieve on-site live working.

Steps for using ZYD two-stage high-efficiency vacuum oil filter

The usage steps of ZYD two-stage high-efficiency vacuum oil filter generally include preparation, starting vacuum, heating and filtering, and shutdown. The specific steps are as follows:

Preparation: Connect the inlet and outlet oil pipes to ensure the power supply is correct.

Start vacuum: Turn on the vacuum pump to establish a vacuum environment.

Heating and filtering: Start the oil pump, and the oil will be heated and filtered to remove impurities.

Shutdown: After the oil filtration is completed, shut down each system in sequence, clean the oil filter, and disconnect the power supply.

LY Plate and Frame Pressure Oil Filter 合集图片pck

Configuration options for ZYD two-stage high-efficiency vacuum oil filter

According to user needs, ZYD two-stage high-efficiency vacuum oil filter can be equipped with various configurations, such as online moisture detector, frequency converter, flow meter with accumulation function, external transformer vacuum system, etc. In addition, the overall structure can also be made into various forms such as mobile, fixed, trailer, etc. to meet the needs of different users.